Product Features Type G(orGH) gravel pumps are designed for continuously handling the most difficult high abrasive slurries which contain too big solids to be pumped by a common pump. They are suitable for delivering slurries in Mining, Explosive sludge in metal melting, Dredging in dredger and river course, and other fields. Type GH are high head pumps. Construction                          Construction of this pump is of single casing connected by means of clamp bands and wide wet-passage. ...


Product Detail

Product Tags

Related Video

Feedback (2)

Our target is always to satisfy our customers by offering golden support, superior value and high quality for , , , Welcome you to be a part of us alongside one another to create your company easier. We're normally your finest partner when you want to have your own organization.
Top Quality 8/6E-G Sand Pump for Ukraine Factories Detail:

Product Features

Type G(orGH) gravel pumps are designed for continuously handling the most difficult high abrasive slurries which contain too big solids to be pumped by a common pump. They are suitable for delivering slurries in Mining, Explosive sludge in metal melting, Dredging in dredger and river course, and other fields. Type GH are high head pumps.

Construction                         

Construction of this pump is of single casing connected by means of clamp bands and wide wet-passage. The wet-parts are made of Ni_hard and high chromium abrasion-resistance alloys. The discharge direction of pump can be oriented in any direction of 360°. This type of pump possesses the advantages of easy installation and operation, good performance of NPSH and abrasion-resistance.

19_副本 

      1.Support                                                8. Discharge Joint Ring 

      2.Bearing Housing Assembly                    9. Discharge Flang

      3.Adapter Plate Clamp Band                    10. Door Clamp Band

      4.Volute Liner Seal                                  11. Cover Plate

      5.Frame Plate Liner Insert                        12. Intake joint ring

      6. Impeller                                               13. Intake flange

      7. Frame Plate / Bowl                              14. Adapter plate

Performance Chart

                  Pump   Model Allowable
Max. Power
(kw)
                                  Clear Water Performance  
 Capacity  Q  Head
  H   (m)
Speed
  n (r/min) 
Max.Eff.
(%)
  NPSH
(m)
 Impeller. Dia.  (mm)
      m3/h                  l/s           
6/4D-G 60 36-250 10-70 5-52 600-1400 58 2.5-3.5 378
8/6E-G 120 126-576 35-160 6-45 800-1400 60 3-4.5 378
10/8S-GH 560 216-936 60-260 8-52 500-1000 65 3-7.5 533
10/8S-G 560 180-1440 50-400 24-30 500-950 72 2.5-5 711
12/10G-G 600 360-1440 100-400 10-60 400-850 65 1.5-4.5 667
12/10G-GH 1200 288-2808 80-780 16-80 350-700 73 2.0-10.0 950
14/12G-G 1200 576-3024 160-840 8-70 300-700 68 2.0-8.0 864
16/14G-G 600 720-3600 200-1000 18-44 300-500 70 3.0-9.0 1016
16/14TU-G 1200 324-3600 90-1000 26-70 300-500 72 3.0-6.0 1270
18/16TU-G 1200 720-4320 200-1200 12-48 250-500 72 3.0-6.0 1067

Applications
The gravel pump is used for river course, reservoir desalting, coastal reclamation, stretching, deep-sea mining and tailing acquisition etc. Gravel pumps are designed for continuously handling the most difficult higher abrasive slurries which contain too big solids to be pumped by a common pump. They are suitable for delivering slurries in Mining, Explosive sludge in metal melting, Dredging in dredger and course of rivers, and other fields.


Product detail pictures:

Top Quality
 8/6E-G Sand Pump  for Ukraine Factories detail pictures


We believe in: Innovation is our soul and spirit. Top quality is our life. Purchaser need is our God for Top Quality 8/6E-G Sand Pump for Ukraine Factories, The product will supply to all over the world, such as: Northern Mariana Islands , Gabon , Haiti , Our faith is to be honest first, so we just supply high quality products to our customers. Really hope that we can be business partners. We believe that we can establish long time business relationship with each other. You can contact us freely for more information and pricelist of our products !


  • ***VISIT OUR SPONSORS***
    http://www.traderadiators.com | http://www.grahamplumbersmerchant.co.uk | http://www.buteline.com/uk | http://www.adey.com

    http://www.plumberparts.co.uk

    ***Facebook***

    http://www.facebook.com/plumberparts

    ***Twitter***

    https://twitter.com/plumberparts

    This video will give you the basic system information needed to understand a vented hot water system. How they work, what the plumbing connections are and where to buy them online

    Please subscribe and favourite!

    Plumberparts.co.uk, honest reviews and advice. Holla, and welcome to today’s Plumberparts.co.uk video. Today, we’re gonna have a look at domestic heating pumps, how you change them, how they work, the things that can go wrong with them, and just everything about them. If we miss anything, let us know as usual and we’ll get back to you. Here is a central heating pump.
    Now, this one is inside a combi boiler, but you can also find them in your airing cupboard or anywhere, really, on the heating circuit that requires flow. They’re generally in the airing cupboard or in the top of your combi boiler. Now, if we look at this one, firstly, you’ll notice that the shaft is actually pointing up in the air. Now, this has been installed incorrectly. If air can get up in the shaft, this would actually seize, so that’s what’s happened with this pump here. It’s actually seized up and it’s not working properly. So, we’ve got a new pump to put in here, so we’re gonna shut these gate valves off here, whip the pump out, do the electrics, pop the pump back in, turn the gate valves on, vent the pump, have it the right way round, and hopefully everything will work fine. One thing to remember is, while it’s not a good idea to have the shaft actually pointing upwards, you can have it pointing horizontally, or any way that air will not get caught in the shaft part in the electronics bit of the actual pump itself. So, never have the pump upwards. Don’t do it, it’s bonkers. So, firstly, isolate the electrics and turn off the heating system, everything, make sure it’s fully isolated. If you’re not competent in doing anything electrics, or anything like that, don’t do it. Once you’ve done that, turn each one of the gate valves off. Once you’ve turned the gate valves off, get a fat screwdriver, undo this, and vent any pressure or water there might be. We do this because then we know that the gate valves are holding. Now, if water still comes out at this point and just keeps on coming out, the gate valves aren’t holding and you’re gonna have to drain the whole system down, which is a complete annoyance. If you don’t know how to drain a pressurised system down, look at our channel, and it’s the same for a feed and expansion system. Just go back to the channel and you’ll find it all there. If we look closely at the inside of this shaft, we’ll see that there’s a small slotted screw bit at the end. Now, if sometimes, the pump can get seized and you can pop a little slotted screwdriver in the end of that, and spin it, and that’ll un-seize the pump, and you never know, you might not need to change it anyway. So, we’ll have a quick look at there and you can see what I mean. So, if we look in here, there’s our slot, our small slot just there, pop our screwdriver in there, and that should move. Now that’s moving alright, but this one’s actually got a burnt out windings. Before you remove a pump, always make a note of the direction of the pump. You’ll find that somewhere on the body, there’ll be a little arrow pointing in the direction that actually pumps the water. Make a note of that and when you put the new pump on, make sure the arrow on that new pump points the same way. Right, so now we get a big set of grips. Now, these can be hard to undo. Oh, these are lovely and loose. Look at that. Beautiful. And that comes off nice and easy. Do that to each end, and there we go. Old pump out of the way. So, it’s a good time once you’ve got the pump out, to check inside each one of these valves, to make sure they’re not all clogged up, ’cause they do get clogged up. The reason for that is there is a magnetic force around the pump, and you have very small particles of metal going round through the water, and they get attracted to this area, and they basically clog it up in the end. So, its always a good idea just to check in there and see how clogged up it is. Let’s have a wee little peek at our new pump. Pumps are all generally the same length, so you should find that it’ll fit in the old slot okay, so that’s great. And also, make sure you don’t lose the fibre washers or the rubber washers. Now, these rubber ones are always a lot better. Fibre ones are just slightly harder to make a seal. They create a seal on the flat here to the flat on the actual pump itself. I’d also recommend as well, when you’re working on these, it doesn’t hurt to get a little file and just file these off so they’re nice and clean.



    If you need Septic Tank Emptying Austin TX services call… us now A septic tank is an underground sewage-collection system. The tank itself is a watertight …

    This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.








    5 Stars By Claire 2016-6-18 15:41
    We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.























    5 Stars By Cindy 2016-3-16 11:41