Manufacturer of G and GH Series Pump Wholesale to India
Short Description:
Product Features Type G(orGH) gravel pumps are designed for continuously handling the most difficult high abrasive slurries which contain too big solids to be pumped by a common pump. They are suitable for delivering slurries in Mining, Explosive sludge in metal melting, Dredging in dredger and river course, and other fields. Type GH are high head pumps. Construction Construction of this pump is of single casing connected by means of clamp bands and wide wet-passage. ...
Product Detail
Product Tags
Related Video
Feedback (2)
Manufacturer of G and GH Series Pump Wholesale to India Detail:
Product Features
Type G(orGH) gravel pumps are designed for continuously handling the most difficult high abrasive slurries which contain too big solids to be pumped by a common pump. They are suitable for delivering slurries in Mining, Explosive sludge in metal melting, Dredging in dredger and river course, and other fields. Type GH are high head pumps.
Construction
Construction of this pump is of single casing connected by means of clamp bands and wide wet-passage. The wet-parts are made of Ni_hard and high chromium abrasion-resistance alloys. The discharge direction of pump can be oriented in any direction of 360°. This type of pump possesses the advantages of easy installation and operation, good performance of NPSH and abrasion-resistance.
1.Support 8. Discharge Joint Ring
2.Bearing Housing Assembly 9. Discharge Flang
3.Adapter Plate Clamp Band 10. Door Clamp Band
4.Volute Liner Seal 11. Cover Plate
5.Frame Plate Liner Insert 12. Intake joint ring
6. Impeller 13. Intake flange
7. Frame Plate / Bowl 14. Adapter plate
Performance Chart
Pump Model | Allowable Max. Power (kw) |
Clear Water Performance | ||||||
Capacity Q | Head H (m) |
Speed n (r/min) |
Max.Eff. (%) |
NPSH (m) |
Impeller. Dia. (mm) | |||
m3/h | l/s | |||||||
6/4D-G | 60 | 36-250 | 10-70 | 5-52 | 600-1400 | 58 | 2.5-3.5 | 378 |
8/6E-G | 120 | 126-576 | 35-160 | 6-45 | 800-1400 | 60 | 3-4.5 | 378 |
10/8S-GH | 560 | 216-936 | 60-260 | 8-52 | 500-1000 | 65 | 3-7.5 | 533 |
10/8S-G | 560 | 180-1440 | 50-400 | 24-30 | 500-950 | 72 | 2.5-5 | 711 |
12/10G-G | 600 | 360-1440 | 100-400 | 10-60 | 400-850 | 65 | 1.5-4.5 | 667 |
12/10G-GH | 1200 | 288-2808 | 80-780 | 16-80 | 350-700 | 73 | 2.0-10.0 | 950 |
14/12G-G | 1200 | 576-3024 | 160-840 | 8-70 | 300-700 | 68 | 2.0-8.0 | 864 |
16/14G-G | 600 | 720-3600 | 200-1000 | 18-44 | 300-500 | 70 | 3.0-9.0 | 1016 |
16/14TU-G | 1200 | 324-3600 | 90-1000 | 26-70 | 300-500 | 72 | 3.0-6.0 | 1270 |
18/16TU-G | 1200 | 720-4320 | 200-1200 | 12-48 | 250-500 | 72 | 3.0-6.0 | 1067 |
Applications
The gravel pump is used for river course, reservoir desalting, coastal reclamation, stretching, deep-sea mining and tailing acquisition etc. Gravel pumps are designed for continuously handling the most difficult higher abrasive slurries which contain too big solids to be pumped by a common pump. They are suitable for delivering slurries in Mining, Explosive sludge in metal melting, Dredging in dredger and course of rivers, and other fields.
Product detail pictures:
With our loaded encounter and considerate services, we have now been recognized as a trustworthy supplier for lots of worldwide consumers for Manufacturer of G and GH Series Pump Wholesale to India, The product will supply to all over the world, such as: Guatemala, Ecuador, Sri Lanka, With more and more Chinese products around the world, our international business is developing rapidly and economic indicators big increase year by year. We have enough confidence to offer you both better products and service, because we are more and more powerful, professional and experience in domestic and international.
1995 Chevy Astro 4 3L
The procedures shown in this video can be applied to a wide variety of GM vehicles over many different model years, that are using a distributor type ignition system.
I will be showing the following:
1. How to test for a fuel pump prime
2. How to test for spark
3. How to test for a distributor reference signal (RPM input)
4. How to bypass the ignition module
5. How to trigger the ECM to fire the injectors and run the fuel pump
6. How to test a fuel pump relay
For more information on this topic, I have written a “field manual” called Engine Performance Diagnostics which is available at www.scannerdanner.com as an eBook or paper book.
Want even more diagnostic training? Whether you are a DIY trying to fix your own car, someone looking to become an auto technician, or a current auto technician that wants to get more into diagnostics, subscribe to ScannerDanner Premium right here on YouTube. There is a 14 day free trial.
On ScannerDanner Premium I will bring you right into my classroom at Rosedale Technical College. You will find page for page lectures taken right from my book as well as exclusive classroom type case studies. What is so special about these classroom case studies? I pull live problem vehicles directly into my classroom and we troubleshoot them in real time, using and applying the theory and testing procedures we learn during the classroom lectures. There is no better on-line training of how to troubleshoot automotive electrical and electronics systems anywhere!
A high-pressure impeller for a turbine cooling pump, manufactured by Egyptian Engineering for Technology (EET) – www.eetechno.com
By Emma 2016-3-28 12:27
The company's products very well, we have purchased and cooperated many times, fair price and assured quality, in short, this is a trustworthy company!
By Ivan 2015-11-22 10:54