Best quality and factory ZGB High Performance Slurry Pump for Gabon Importers

Best quality and factory ZGB High Performance Slurry Pump for Gabon Importers

Short Description:

Introduction In order to meet the requirements on the development of the electric power, metallurgy and coal industries, our factory has designed and developed series ZGB(P) up-to-date generation slurry pump with large capacity, high head, multi-stages in series to remove ash & sludge and to deliver liquid-solids mixture, based on the experience of slurry pump design and manufacture for many years, and abstracting the research results of advanced technology from home and abroad. The main ...


Product Detail

Product Tags

Related Video

Feedback (2)

To meet the customers' over-expected pleasure , we have now our solid crew to supply our greatest all round assistance which includes marketing, sales, planning, production, top quality controlling, packing, warehousing and logistics for , , , We have now confident that we can easily offer the premium quality products and solutions at resonable price, good after-sales services into the buyers. And we're going to produce a dazzling future.
Best quality and factory ZGB High Performance Slurry Pump for Gabon Importers Detail:

Introduction

In order to meet the requirements on the development of the electric power, metallurgy and coal industries, our factory has designed and developed series ZGB(P) up-to-date generation slurry pump with large capacity, high head, multi-stages in series to remove ash & sludge and to deliver liquid-solids mixture, based on the experience of slurry pump design and manufacture for many years, and abstracting the research results of advanced technology from home and abroad. The main technical features are as follows,

CAD modern design , super hydraulic performance, high efficiency and lower abrasive rate;

Wide passage, non-clogging and good performance of NPSH;

Expeller seal combined with packing seal and mechanical seal have be adopted to guarantee the slurry from leakage;

Reliability design ensures long MTBF (mean time between events);

The metric bearing with oil lubrication, reasonable lubrication and cooling systems ensure the bearing to be operated under the low temperature;

The materials of wet parts have the good performance of anti-wearing and anti-corrosion.

The pump can be used for seawater ash-removing to prevent it from the corrosion of seawater, salt and mist, and electrochemical corrosion;

The pump can be operated in series with multi-stage within permissible pressure.

The permissible maximum working pressure is 3.6MPa.

The series of pump has the advantages of reasonable construction, high efficiency, reliable operation and easy maintenance. It can be widely used for handling the mixture contained of abrasive and corrosive solids in electric power, metallurgy, mine, coal, constructional material and chemical industry departments, especial for removing ash and sludge in electric power station.

Product Features

1. The series ZGB(P) slurry pump is of horizontal, single-stage, single-suction, cantilever, double-casing, centrifugal slurry pump. The pump rotates in clockwise viewed from the drive end.

2. The wet parts of ZGB and ZGBP pump at the same outlet diameter can be interchangeable. Their outline installation dimensions are one and the same. For the drive part of the series ZGB(P) slurry pump, the horizontal split frame with oil lubrication and two sets of water cooling systems inside and outside has been adopted. If necessary, cooling water can be supplied. The prepared joint for cooling water and the pressure of the cooling water can be seen in table 1.

3. Two kinds of shaft seal—expeller seal combined with packing and mechanical seal have been used for series ZGB(P) slurry pump.

4. The mechanical seal supplied with high pressure sealing water is recommended when the slurry pump is operated in series(two stages and above two stages), and the expeller seal combined with packing is used    in  single-stage pump.

Technical Parameters

Pump Model  Speed  n(r/min) Capacity Q  (l/s)   Head     H (m) Max.Eff.
(%)
 NPSH
(m)
Shaft  Power  (kw)  Impeller Dia (mm) Pump Weight (kg) Outlet Dia./Inlet Dia. (mm)
65ZGB 1480 31.7-15.8 58-61 62.5-47.4 4.5-3.0 28.8-19.9 390 1850 65 / 80
980 21.0-10.5 25.4-26.7 62.5-47.4 2.0-1.3 8.37-5.8
80ZGB 980 56.7-28.3 87.5-91.6 66.1-48.7 5.2-2.7 73.7-52.2 485 2500 80 / 100
740 37.5-18.8 38.4-40.2 66.1-48.7 2.3-1.2 21.4-15.2
980 52.0-26.0 73.7-77.1 66.1-48.7 4.4-2.3 56.8-40.4 445
740 34.4-17.2 32.3-33.8 66.1-48.7 1.9-1.0 16.5-11.7
980 46.8-23.3 59.5-62.3 66.1-48.7 3.5-1.8 41.3-29.2 400
740 31.0-15.4 26.1-27.3 66.1-48.7 1.5-0.8 12.0-8.4
100ZGB 1480 116.7-58.3 85.1-91.8 77.9-57.4 6.0-2.6 124.9-91.4 500 3000 100 / 152
980 77.3-38.6 37.3-40.3 77.9-57.4 2.7-1.2 36.3-26.6
1480 105-52.5 68.9-78.4 77.9-57.4 4.9-2.1 91.0-66.7 450
980 69.5-34.8 30.2-32.6 77.9-57.4 2.1-1.1 26.4-19.4
1480 93.4-46.7 54.5-58.8 77.9-57.4 3.8-1.7 64.0-46.9 400
980 61.8-30.9 23.9-25.8 77.9-57.4 1.7-0.8 18.6-13.6
150ZGB 980 200-100 85.2-90.0 77.7-53.3 3.8-2.7 215.0-165.5 740 3450 150 / 200
740 151.2-75.6 48.6-51.3 77.7-53.3 2.2-1.5 92.7-71.3
980 182.4-91.2 73.0-77.1 77.7-53.3 3.3-2.3 168.0-129.3 685
740 140.0-70.2 41.6-44.0 77.7-53.3 1.9-1.3 74.2-56.8
980 169.2-84.6 61.8-65.2 77.7-53.3 2.8-1.1 131.9-101.5 630
740 129.6-64.8 35.2-37.2 77.7-53.3 1.6-0.6 57.6-44.3
200ZGB 980 300.0-150.0 89.0-94.2 76.3-63.2 6.7-2.7 342.9-219.1 740 4000 200 / 250
740 226.5-113.3 50.7-53.7 76.3-63.2 3.8-1.5 147.5-97.3
980 283.8-141.9 79.6-84.3 76.3-63.2 6.0-2.4 290.2-185.8 700
740 214.3-107.1 45.4-48.1 76.3-63.2 3.4-1.4 125.0-80.0
980 259.5-129.7 66.6-70.5 76.3-63.2 5.0-2.0 222.0-141.8 640
740 195.9-97.9 38.0-40.2 76.3-63.2 2.9-1.1 95.6-61.0
250ZGB 980 400.0-200.0 84.0-90.1 78.2-63.2 7.3-3.3 421.2-275.6 740 4500 250 / 300
740 302.0-151.0 47.9-51.4 78.2-63.2 4.2-1.9 181.4-118.7
980 378.4-189.2 75.2-80.6 78.2-63.2 7.1-3.0 356.7-233.2 700
740 285.7-142.9 42.9-46.0 78.2-63.2 4.0-1.7 153.7-100.5
980 348.6-131.6 63.8-68.5 78.2-63.2 5.5-2.5 278.8-137.9 645
740 263.2-99.4 36.4-39.1 78.2-63.2 3.1-1.4 120.1-59.4
300ZGB 980 533.3-266.7 84.3-93.4 81.2-68.3 6.9-3.5 542.8-357.6 760 5500 300 / 350
740 402.7-201.3 48.1-53.3 81.2-68.3 3.9-2.0 233.9-154.0
980 493.3-246.7 72.1-79.9 81.2-68.3 5.9-3.0 429.4-282.9 703
740 372.5-177.9 41.1-45.6 81.2-68.3 3.4-1.7 184.8-116.4
980 453.3-226.7 60.9-67.5 81.2-68.3 5.0-2.5 333.3-219.7 646
740 342.3-171.2 34.5-38.5 81.2-68.3 2.9-1.4 143.4-94.6

The water pressure and amount of all kinds of the shaft seal is as follows

Sealing water pressure

For single-stage pump with the expeller seal combined with packing, the water pressure of the shaft seal is 0.2-0.3MPa.

For multi-stage(two and above two stages) in series operation with the expeller seal combined with packing, the sealing water pressure should be:

The lowest sealing water pressure of n stage

Pn=  QQ图片20170302144648Hi+0.7Hn;Hi is i stage pump head;Hn is n stage pump head.

For mechanical seal, the sealing water pressure of each stage of pump is higher 0.1MPa than pump discharge pressure.

Sealing water pressure(see table 1)17


Product detail pictures:

Best quality and factory ZGB High Performance Slurry Pump for Gabon Importers detail pictures


With our leading technology also as our spirit of innovation,mutual cooperation, benefits and advancement, we'll build a prosperous future together with your esteemed organization for Best quality and factory ZGB High Performance Slurry Pump for Gabon Importers, The product will supply to all over the world, such as: luzern, Mozambique, Latvia, Our products have been obtained more and more recognition from foreign clients, and established long term and cooperative relationship with them. We`ll provide the best service for every customer and sincerely welcome friends to work with us and establish the mutual benefit together.


  • How to fit or replace a shower pump. We show you it all. For more reviews on showers pumps and how they work or for more plumbing tips visit our website at https://www.plumberparts.co.uk

    ***VISIT OUR SPONSORS***
    https://www.traderadiators.com | https://www.grahamplumbersmerchant.co.uk | https://www.buteline.com/uk | https://www.adey.com

    This instructional video will show you how to install or replace a shower pump.
    For the purposes of this video we are installing a Grundfos Niagra 1.5 bar
    shower pump. But this video will work for Salamander, Grundfos Amazon, Grundfos nile and Stuart turner. The 1.5 bar relates to the pressure output delivered by the pump.
    When you receive a pump they often come with flexible hoses supplied. This makes the
    installation much easier. These are rubber washers to use in water connection.
    They’re very important so don’t lose them. If we look closely we can see the
    water supply inlet and the rubber feet. These disperse
    any vibration caused by the pump in operation. On the outlet of the pump there are two
    pressure sensors. When the
    pressure drops due to a shower being opened the sensors activate the pump.
    Before doing any work on a shower pump ensure it is electrically isolated by switching it
    off and pulling the fuse. Remove the electrical box cover and remove the wires
    once you have ensured they are not live by using a volt meter.
    Turn off the hot and cold water supply to the pump.
    Remove the pump water connections, making a note of which ones are the inlet and
    the outlet.
    Sometimes water is still in the pipes so have a bucket or towel handy to catch any drips.
    Remove the old pump.
    Fortunately the new pump is the same model so no major alteration in
    pipework is required.
    Use the rubber washer supplied to make a watertight seal. Ensure the washer with the gauze filter
    is on the inlet. This protects the pump from any debris in the water. Tighten all joints right up and turn on the water supply. Check for leaks.
    Now remove the electrical cover of the new pump. Thread your wire through the nut, rubber washer and cover before connecting the wires. Identify which wires go in which terminal and using a small slotted screwdriver tighten them in place.
    Now replace your electrical cover.
    It’s often a good time to try and purge your system of air before running the pump. Do this by opening your shower valve.Turn on the electrics and test pump operation by using the shower.

    We have been engaged in this industry for many years, we appreciate the work attitude and production capacity of the company, this is a reputable and professional manufacturer.









    5 Stars By Andy 2016-6-18 17:47
    Adhering to the business principle of mutual benefits, we have a happy and successful transaction, we think we will be the best business partner.






















    5 Stars By Edward 2016-2-27 17:52