Hot sale Factory G and GH Series Pump to Liverpool Factory

Hot sale Factory
 G and GH Series Pump  to Liverpool Factory

Short Description:

Product Features Type G(orGH) gravel pumps are designed for continuously handling the most difficult high abrasive slurries which contain too big solids to be pumped by a common pump. They are suitable for delivering slurries in Mining, Explosive sludge in metal melting, Dredging in dredger and river course, and other fields. Type GH are high head pumps. Construction                          Construction of this pump is of single casing connected by means of clamp bands and wide wet-passage. ...


Product Detail

Product Tags

Related Video

Feedback (2)

Our target is always to satisfy our customers by offering golden support, superior value and high quality for , , , We welcome new and outdated shoppers from all walks of lifetime to call us for long term company associations and mutual accomplishment!
Hot sale Factory G and GH Series Pump to Liverpool Factory Detail:

Product Features

Type G(orGH) gravel pumps are designed for continuously handling the most difficult high abrasive slurries which contain too big solids to be pumped by a common pump. They are suitable for delivering slurries in Mining, Explosive sludge in metal melting, Dredging in dredger and river course, and other fields. Type GH are high head pumps.

Construction                         

Construction of this pump is of single casing connected by means of clamp bands and wide wet-passage. The wet-parts are made of Ni_hard and high chromium abrasion-resistance alloys. The discharge direction of pump can be oriented in any direction of 360°. This type of pump possesses the advantages of easy installation and operation, good performance of NPSH and abrasion-resistance.

19_副本 

      1.Support                                                8. Discharge Joint Ring 

      2.Bearing Housing Assembly                    9. Discharge Flang

      3.Adapter Plate Clamp Band                    10. Door Clamp Band

      4.Volute Liner Seal                                  11. Cover Plate

      5.Frame Plate Liner Insert                        12. Intake joint ring

      6. Impeller                                               13. Intake flange

      7. Frame Plate / Bowl                              14. Adapter plate

Performance Chart

                  Pump   Model Allowable
Max. Power
(kw)
                                  Clear Water Performance  
 Capacity  Q  Head
  H   (m)
Speed
  n (r/min) 
Max.Eff.
(%)
  NPSH
(m)
 Impeller. Dia.  (mm)
      m3/h                  l/s           
6/4D-G 60 36-250 10-70 5-52 600-1400 58 2.5-3.5 378
8/6E-G 120 126-576 35-160 6-45 800-1400 60 3-4.5 378
10/8S-GH 560 216-936 60-260 8-52 500-1000 65 3-7.5 533
10/8S-G 560 180-1440 50-400 24-30 500-950 72 2.5-5 711
12/10G-G 600 360-1440 100-400 10-60 400-850 65 1.5-4.5 667
12/10G-GH 1200 288-2808 80-780 16-80 350-700 73 2.0-10.0 950
14/12G-G 1200 576-3024 160-840 8-70 300-700 68 2.0-8.0 864
16/14G-G 600 720-3600 200-1000 18-44 300-500 70 3.0-9.0 1016
16/14TU-G 1200 324-3600 90-1000 26-70 300-500 72 3.0-6.0 1270
18/16TU-G 1200 720-4320 200-1200 12-48 250-500 72 3.0-6.0 1067

Applications
The gravel pump is used for river course, reservoir desalting, coastal reclamation, stretching, deep-sea mining and tailing acquisition etc. Gravel pumps are designed for continuously handling the most difficult higher abrasive slurries which contain too big solids to be pumped by a common pump. They are suitable for delivering slurries in Mining, Explosive sludge in metal melting, Dredging in dredger and course of rivers, and other fields.


Product detail pictures:

Hot sale Factory
 G and GH Series Pump  to Liverpool Factory detail pictures


Our firm promises all consumers with the first-class products as well as most satisfying post-sale services. We warmly welcome our regular and new consumers to join us for Hot sale Factory G and GH Series Pump to Liverpool Factory, The product will supply to all over the world, such as: Senegal , Australia , Jordan , Our mission is to deliver consistently superior value to our customers and their clients. This commitment permeates everything we do, driving us to continuously develop and improve our products and the processes to fulfill your needs.


  • How to remove the central locking,headrest etc. vacuum pump from a 1998 Mercedes clk w208…other Mercedes models are similar if not identical follow me on twitter https://twitter.com/fupabox



    With Asetek liquid cooling, you may experience pump noise when installing your cooler for the first time or after relocating your system. The noise is typically caused by air bubbles moving through the pump. It generally goes away on its own within 15 minute of starting up, but here are a few ways you can minimize air bubbles in your system.

    When installing your liquid cooling, ensure that at least a portion of the hex is higher than the pump. Also, install it with the tubes entering at the bottom of the hex when installing at the rear or side panel of a case. In some cases, it may help to uninstall your hex and shake it to help move the air bubbles along.

    Here’s an example of a noisy pump. If we shake it, the air bubbles go away.

    These steps should ensure your liquid cooling performs as quietly as possible.

    The manufacturer gave us a big discount under the premise of ensuring the quality of products, thank you very much, we will select this company again.

    5 Stars By Christine 2016-9-29 19:19
    The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.