8 Years Manufacturer 450WN Dredge Pump for Accra Manufacturers

8 Years Manufacturer
 450WN Dredge Pump  for Accra Manufacturers

Short Description:

Product Introduction WN (Q) dredging pump is a kind of highly effective wear-resistant marine dredging pump, which is based on absorption of abroad technology. WN (Q) dredging pump meets the comprehensive dredging requirement at home and abroad. Features Overall structure performance well in marine use Simple and reliable structure: 200WN-500WN and 600WNQ-1000WNQ type dredge pump with a single pump casing or double pump casing, single stage single suction cantilever horizontal structure. Acco...


Product Detail

Product Tags

Related Video

Feedback (2)

Good quality comes initial; company is foremost; small business is cooperation" is our business philosophy which is frequently observed and pursued by our business for , , , We are very proud of the good reputation from our customers for our products' reliable quality.
8 Years Manufacturer 450WN Dredge Pump for Accra Manufacturers Detail:

Product Introduction

WN (Q) dredging pump is a kind of highly effective wear-resistant marine dredging pump, which is based on absorption of abroad technology. WN (Q) dredging pump meets the comprehensive dredging requirement at home and abroad.

Features

Overall structure performance well in marine use

Simple and reliable structure: 200WN-500WN and 600WNQ-1000WNQ type dredge pump with a single pump casing or double pump casing, single stage single suction cantilever horizontal structure. According to the connection type with the gear box, there are two kinds of typical structure, one is with independent support, the other is combined with gear box. The lubrication of pump with support is grease lubrication or thin oil lubrication. The double casing design can make the pump body safe even when the liner is worn out. Easy to disassemble and  maintenance: WN type dredging pump can be disassembled from front. This make the disassemble and maintenance easier.

Good performance of dredging

Good cavitation performance: WN type dredging pump have good cavitation performance which can ensure suction ability of pump. While it can achieve greater digging depth and higher suction concentration.

High flow capacity and wide applicability: WN type dredge pump impeller passage is very wide to continuous pumping gravel or high plastic clay and not happens jam. Good carrying ability of pump is guarantee for dredger performance.

Sharp Dropping performance curve: The flow and head curve falling steeply makes the mud pump having a stronger adaptability to the change of row spacing.

Achieving various blendings of pump performance: WN dredging pump can change the rotational speed and the diameter of the impeller, to achieve the different head of pump under the same flow.

Wear-resistant and long-life service wet parts

Wet parts of WN dredging pump , such as impeller, volute liner, throat bushing and frame plate liner insert(wearable liner) adopt alloy cast iron material whose hardness is not less than 58HRC. It has not only impact on resistance but also high anti-abrasion performance.

The service life of each part is fully considered in the process of product design. The same replacement cycle reduces the maintenance and replacement costs.

Small hydraulic loss, high efficiency, low power consumption: Due to the advanced hydraulic model, the dredging pump has high efficiency level. The efficiency of WN dredging pump is higher about 2-3 percentage points than imported. Thus, in the same production, it can achieve lower fuel consumption.

A reliable seal and no leakage

200WN-500WN dredge pump adopts mechanical seals or packing seals or combination of  mechanical and packing seals.

600WN(Q)-1000WN(Q) dredge pump adopts shaft seal with L-shaped screw shell rubber seal device which has three L-shaped seal rings and one shaft sleeve with special thread.

Technical Parameters

                                       Pump    Model
 Capacity Q (m3/h)
  Head   H  (m)      Speed   n   (r/min)          Eff.        (%)      NPSHr     (m)    Inlet     Diameter (mm)      Outlet       Diameter (mm)
Max.  Diameter of Flowd Particle  (mm)
200WNQ 600-800 20-40 700-900 60-65 <4.5 250 200 178
200WN 750-1000 40-65 700-850 70-72 <4 250 200 180
250WNQ 950-1100 20-40 500-700 65-70 <4 300 250 220
250WN 1100-1300 40-65 500-650 70-74 <4 350 250 144
300WNQ 1500-1800 20-40 400-600 65-68 <4 350 300 241
300WN 1800-2200 40-65 400-550 74-78 <4 450 300 241
350WN 2600-3000 40-65 400-550 74-78 <4.5 450 350 245
400WN 2800-3200 20-40 400-550 74-78 <4.5 450 400 250
450WN 3200-3850 40-67 350-500 76-80 <4.5 600 450 354
500WNQ 3600-4200 20-40 220-320 72-75 <4.8 600 500 330
500WN 4500-5500 30-72 350-450 78-80 <4.8 650 500 250
600WN 5000-9000 30-75 280-420 81-85 <6 660 600 220
700WN 8000-12000 30-76 280-380 83-85 <6 760 700 280
800WN 10000-15000 28-72 260-350 80-84 <6 900 800 300
900WN 12000-19000 25-75 220-330 85-87 <6 960 900 320
1000WN 16000-25000 23-76 181-290 85-87 <6 1200 1000 350

Product detail pictures:

8 Years Manufacturer
 450WN Dredge Pump  for Accra Manufacturers detail pictures


We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate in our success for 8 Years Manufacturer 450WN Dredge Pump for Accra Manufacturers, The product will supply to all over the world, such as: Mauritius , Frankfurt , Argentina , We have been persisting in the business essence "Quality First, Honoring Contracts and Standing by Reputations, providing customers with satisfying goods and service. " Friends both at home and abroad are warmly welcome to establish everlasting business relations with us.


  • Still on the fence to keep or sell.



    A brief video about Pressurised Heating Systems. How to drain them and fill them up. How to vent air from them. How to pressurise them. For more information visit our website at http://www.plumberparts.co.uk

    DIY

    In this video I’m going to tell you how to drain down a pressurised heating system. This particular system doesn’t have a feed and expansion tank in the loft or a ball valve for you to hold up or anything like that. It’s completely sealed and airtight
    so you have an expansion vessel, cold water fill and a pressure valve, and a pressure release valve as well. I’ve managed to locate the pressurization filling loop and I’ll just show you that now. Here’s the pump, that’s the flow from the boiler. This pipe coming down here is the feed pipe Here is our expansion tank. That will take any expansion for when the water heats up. So, there is a rubber diaphragm in there This side is air and this side here is water. THen we have our pressure gauge which currently reads about 1 bar when it’s cold.
    The heating system should be at about 1 and a half bar when it’s warm.
    There’s our first valve from the mains comes down here and there’s our second valve there. turn both of those off. Remember when draining any system
    to open up any 3-port or 2-port valves.
    put our hose on and drain the system down.
    You have your boiler with it’s flow to the radiator and it’s return back.
    You’ll have a cold feed coming in to a
    valve, then a hose that you saw upstairs when I showed you
    That will go through a manifold that connects to the expansion vessel. This has a rubber diaphragm inside. On one side of that you have water
    and on the other side you have air. There is a small schrader valve so that you can pump the air
    bag up to a certain pressure.
    Usually you’ll pump it up to 1 bar
    Also you have a high pressure relief valve. Now, for safety reasons there should never be any valves between the
    heating system or the components of the expansion vessel and the high
    pressure relief valve. That’s very important. When testing the air pressure in the air side of the expansion
    vessel, only ever do that when the system is drained down and there is no water pressure in there otherwise
    you’ll get a false reading. There is
    also a check valve that in a situation where the heating system pressure got above that
    of the cold water mains coming in, you couldn’t push heating system water back
    into the main supply come downstairs and find the
    lowest point of the system. Here’s our drain off just here on this lowest radiator.
    So, pop a hose on here. Open that fully up and then go back upstairs.
    So we come up here, open this air vent up
    make sure that these two valves are open so the thermostatic valve
    is fully open and the lockshield at the other end is open
    and open up the valve. Do that to every
    other radiator upstairs and after about 10 minutes, and do it to all of the rads downstairs.
    If you’re working on the radiators just upstairs
    then you won’t need to drain the one downstairs, will you? Once all the
    water has stopped coming out of the end of your hose and you’ve vented all the radiators that you want to work on upstairs and downstairs you can now work on everything
    You can now fill the system up again.
    Right, remove your hose and then shut off your drain off.
    go upstairs and go around all of the radiators upstairs and downstairs and shut all their air vents.
    go back to where the pressurization unit is and the fill loop is and open those valves and start to fill the system
    Just open that. Now we are reintroducing
    water into the system. You should see dial start to
    rise as pressure starts to build.
    Pressurize it up to about one and a half bar, then go back downstairs to the
    radiators and vent them out.
    As soon as there’s no more air coming
    out and it all stops go back upstairs and top the system up again
    Keep going around doing that until you have water coming out of each radiator and you’ve turned it off
    and then as soon as that’s done go back upstairs, pressurize the system to one bar and
    you should be done. what you do is pressurize it up to a bar, you
    bleed the rads. When no more air comes out shut that radiator. Go back upstairs
    repressurize to a bar, open that radiator, Leave the system at one bar
    and then when it comes and gets hot and you turn it all on it should only get up to
    one and a half bar

    ***VISIT OUR SPONSORS***
    http://www.traderadiators.com | http://www.grahamplumbersmerchant.co.uk | http://www.buteline.com/uk | http://www.adey.com

    The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!