Introduction Type L(R) pumps are cantilevered, horizontal, centrifugal slurry pumps, which are also called light duty slurry pump. They are suitable for delivering low abrasive low density slurry for metallurgical, mining, coal and building material departments. The shaft seal can adopt  gland seal, expeller seal or mechanical seal. Type L(R) pumps operate in high speed with small volumes and light weight to save floor area. It is mainly used to transport the slurry which contains fine partic...


Product Detail

Product Tags

Related Video

Feedback (2)

To consistently enhance the management method by virtue of the rule of "sincerely, fantastic religion and top quality are the base of business development", we extensively absorb the essence of associated goods internationally, and constantly acquire new merchandise to satisfy the needs of shoppers for , , , We feel that a passionate, ground breaking and well-trained workforce can create fantastic and mutually useful business associations with you quickly. Be sure to really feel totally free to contact us for more particulars.
12 Years Factory wholesale L Metal Light Duty Slurry Pump to Canberra Manufacturers Detail:

Introduction

Type L(R) pumps are cantilevered, horizontal, centrifugal slurry pumps, which are also called light duty slurry pump. They are suitable for delivering low abrasive low density slurry for metallurgical, mining, coal and building material departments. The shaft seal can adopt  gland seal, expeller seal or mechanical seal.

Type L(R) pumps operate in high speed with small volumes and light weight to save floor area. It is mainly used to transport the slurry which contains fine particle size and weight concentration not more than 30%. The liner and impeller of this pump can be changeable ,eight with anti-abrasive metal or rubber material.

Advantages
1. Discharge branch can be positioned at intervals of 45 degree. 
2. Good replaceability of components with original pump. 
3. Wear-resistant metal and long service life time. 
4. With greater axial and radial load rating capacity, 
5. Discharge direction can be installed at intervals of 45 degrees as request and oriented to any eight positions to suit applications. 
6. Suit different working condition.
7. Wide application, high efficiency and easy to maintain. 
8. Wide options for impeller. 
9. Bearing assembly use grease lubrication. 

Type Notation

25

Technical Parameters

     Pump  Model   Allowable
Max. Power (kw)
 Clear Water Performance   
Capacity  Q Head
H
      (m)          
        Speed 
  n  (r/min)       
Max.Eff.
(%)
  NPSH
(m)       
 Impeller. Dia.  (mm)   
  m3/h              l/s     
20A – L 7.5 2.34-10.8 0.65-3 6-37 1400-3000 40 2.5-3 152.4
50B – L 15 11.5-76 3.2-21.1 8.5-46 1400-2800 62 2.5-5.5 190
75C – L 30 18-151 5-42 4-46.4 900-2400 57 3-6 229
100D – L 60 46.8-324 13-90 7-48.3 800-1800 64 2-6 305
150E – L 120 115-568.8 32-158 10.5-51.8 800-1500 60 2.5-6 381
200E – L 120 234-910 65-235 9.5-40 600-1100 64 3-6 457
250E – L 120 396-1425 110-396 8–30 500-800 77 2-10 550
300S – L 560 468-2538 130-708 8-60 400-950 79 2-10 653
350S – L 560 650-2800 180-780 10-59 400-840 81 3-10 736
400ST – L 560 756-3312 210-920 7-37.5 300-600 85 2-8 825
450ST – L 560 1080-4356 300-1210 9-40 300-550 87 3-10 933
550TU – L 1200 1980-7920 560-2200 10-50 250-475 86 4-10 1213
650TU – L 1200 2520-9108 700-2530 10-55 200-350 86 2-8 1425
50B – L(R) 15 9-61 2.5-17 3-32.4 1200-2600 48 2.75-4.5 190
75C – L(R) 30 28.8-154.8 8-43 9-43 1100-2300 60 3-5 229
100D – L(R) 60 54-288 15-80 12-38 800-1600 65 2.5-5.5 305
150E – L(R) 120 72-576 20-160 4-38 800-1300 65 2.5-5.5 381
250E – L(R) 120 396-1425 110-396 8-30 500-800 77 2-10 550
300S – L(R) 560 432-1900 120-528 7-41 400-800 81 3-8 653
350S – L(R) 560 720-2844 200-790 10-41 400-700 86 3-7 736
400ST – L(R) 560 720-3312 200-920 7-51 300-700 80 2-10 825
450ST – L(R) 560 1008-4356 280-1210 9-48 300-600 80 2-9 933
550TU – L(R) 1200 1980-7920 560-2200 10-50 250-475 86 4-10 1213
650TU – L(R) 1200 2520-9108 700-2530 10-39 200-350 86 2-8 1425
Remark:
1. Capacity range recommended: 50%Q’≤Q≤110%Q’(Q’ Appropriate to capacity at highest efficiency point).
2. NPSH: appropriate to point Q recommended at highest speed                                                                                                                      

Selection Chart 

24

Application
L(R) series slurry pump is widely used in metallurgy, mining, mineral processing, dredging, dewatering, water treatment, coal washing, mill, cyclone feed, tailing, power, building material…etc. various industrial sites. Our pumps are called different names for different working duties: Mineral processing pump, Mill discharge slurry Pump, Booster pump, Feeding pump, Tailing pump, Transfer pump Thickner Underflow Pump, De-watering screen pump, Pressure pump, Concentrate pump…

 


Product detail pictures:

12 Years Factory wholesale
 L Metal Light Duty Slurry Pump to Canberra Manufacturers detail pictures


We insist over the principle of development of 'High top quality, Performance, Sincerity and Down-to-earth working approach' to supply you with exceptional services of processing for 12 Years Factory wholesale L Metal Light Duty Slurry Pump to Canberra Manufacturers, The product will supply to all over the world, such as: Cairo , Greenland , Liberia , Based on experienced engineers, all orders for drawing-based or sample-based processing are welcomed. We have now won a good reputation for outstanding customer service among our overseas customers. We will continue to try the best to supply you good quality products and solutions and the best service. We've been looking forward to serving you.


  • http://current-usa.com – Learn about the different Eflux DC Flow Pumps and easy installation tips, like how to size a Eflux DC Flow pump and aquarium flow pump installation tips.

    Eflux water flow pumps provide a safe, controllable solution for pumping water in your aquarium. These low-voltage pumps are controllable. Each one has a dial that lets you adjust water flow easily. They even save money in electrical consumption.

    Learn what size DC pump is best for your aquarium. It’s a simple formula: Entire system volume x 5. This ensures you get five time turnover rate per hour. Use that number compared to our flowchart to find right DC flow pump model.

    We compare 3 pump models :
    - Smallest, Model 6009
    - Medium, Model 6010
    - Largest, Model 6011

    There are simple tips to ensure your pump is installed correctly. For example, make sure to clean your flow pumps every 8 – 12 months because coralline algae can build up.

    Learn more at http://current-usa.com/pumps/eflux-dc-flow-pumps/.

    Questions? Ask in comments below. For more aquarium tips? Subscribe!



    Material Requirements:
    * pvc sheet / cardboard for house: size: 1 ft x 2 ft
    * 6 volt DC motor: 1 no
    * 6 spoon
    * LED as a s
    * coloring tape.
    *flexkwick
    * scissor and cutter
    * small pulley and rubber

    Plz Subscribe my channel for new videos.

    Follow us:

    https://www.facebook.com/etechgrp/

    www.instagram.com/etechgroup/

    Visit Us: www.etechgrp.com

    Mail Us: info@etechgrp.com

    check my new channel for mobile hack:

    https://www.youtube.com/channel/UCGn7UpxOMtrfMMmmRcFVQgQ

    The company keeps to the operation concept "scientific management, high quality and efficiency primacy, customer supreme", we have always maintained business cooperation. Work with you,we feel easy!





















    5 Stars By Alex 2016-2-22 12:22
    After the signing of the contract, we received satisfactory goods in a short term, this is a commendable manufacturer.





    5 Stars By Steven 2016-6-26 15:38